Local-only Web Audio workbench · no prompt on load · no audio upload
Audio Tester Mic: Live dBFS Level Meter, Noise-Floor Calibration, SNR and Clipping Alerts
Turn the microphone into a proper level meter: a segmented −60 to 0 dBFS bar with peak hold, a three second noise-floor calibration, a speech measurement, a real signal-to-noise ratio and a four-state gain verdict that tells you what to change.
Interactive microphone workbench
Stored only in this tab and in optional #m= share links (up to 80 graphemes, clipped by grapheme cluster rather than by a raw maxlength).
Microphone diagnostics and live levels
AEC off · NS off · AGC off · speech −∞ dBFS (Silence) · floor −∞ dBFS (Silence)
−∞ dBFS (Silence) live · peak hold −∞ dBFS (Silence) · Too Quiet
Speech this low will be buried by room noise. Move closer, raise the interface gain, or disable auto gain control and set the level by hand.
Level Meter Report
Speech −∞ dBFS (Silence) · noise floor −∞ dBFS (Silence) · SNR Not measured yet · clipped 0 · floor target not measured.
| Reading | Value | Reference |
|---|---|---|
| Speech level | −∞ dBFS (Silence) | -24 to -12 dBFS |
| Noise floor | −∞ dBFS (Silence) | at or below −55 dBFS |
| Signal to noise | Not measured yet | 30 dB or better |
| Clipped samples | 0 | zero |
| Processor chain | AEC off / NS off / AGC off | as reported by the browser |
Mic Test · everything measured locally in the browser; no audio is uploaded.
Capture, the waveform and spectrum views, the dBFS maths, the 16-bit PCM WAV encoder and every replay run inside this tab. No audio upload, no account, no microphone prompt on load, and no third-party player.
Reading a decibel meter that never lies about silence
The meter is drawn from the analyser’s time-domain window, not from a CSS animation, so the bar you see is the level the page measured about twenty times per second. The scale runs from −60 dBFS at the left edge to 0 dBFS at the right, split into green, amber and red segments, and a peak-hold marker keeps the loudest recent value visible long enough to read after you stop talking.
Silence is handled explicitly. Twenty times log base ten of zero is negative infinity, which is not a value a page should ever print as a raw error token or a bare infinite sign, so the readout becomes −∞ dBFS (Silence) and the bar collapses to zero width. The same rule holds in the CSV, the printed card and the share link: there is exactly one way to say nothing was captured, and it is a sentence rather than an error.
The clipping counter is separate from the level bar. Every sample whose absolute value reaches 0.999 increments it, and any level at or above −0.5 dBFS also flips the gain verdict to Clipping. The counter is cumulative for the current input session and resets when you press Stop or Reset, so a clean session really shows zero rather than a counter that was never running.
Calibrating the room and computing a real SNR
Press Calibrate Noise Floor and stay quiet for three seconds. The page averages the level across that window and stores it as the room tone, which is the denominator of every signal-to-noise calculation that follows. The number is a property of the room plus the microphone plus the processor chain, so switching noise suppression on and repeating the calibration is a genuinely useful experiment rather than a formality.
Then press Measure Speech and speak in your normal voice. The page records the speech level, and the signal-to-noise ratio is simply the speech level minus the noise floor, both in dBFS. Subtracting decibels is dividing linear amplitudes, so a speech level of minus 18 dBFS over a floor of minus 62 dBFS is a 44 dB ratio: every doubling of noise amplitude adds about six decibels, so that gap is a wide margin.
A healthy quiet room measures under −55 dBFS with the microphone where you actually sit. Laptops, air conditioning, a nearby fan and an unshielded interface can all push the floor above −45 dBFS, and no amount of gain fixes that: raising gain lifts the noise with the voice. Treat the calibration as a diagnostic, not a badge, and move the microphone or the noise source before you touch the gain.
The four gain verdicts and what to do about each
Too Quiet means speech is below the −24 dBFS working floor. The fix is proximity first, gain second: a microphone at fifteen centimetres needs far less preamp gain than one at sixty, and moving it changes the ratio of direct sound to room sound as well as the level. If the level is still low with auto gain control off and the gain near maximum, the capsule or the interface is the limit.
Optimal Speech is the band between −24 and −12 dBFS, where there is room for a laugh or a plosive without hitting full scale. Hot means above −12 dBFS, so the next loud syllable will clip and the fix is a small step back rather than a large one. Clipping means the waveform is already flat-topped, and the only real repair is to record the take again at a lower level, because a squared-off peak cannot be restored.
Every verdict comes with the number that produced it, and every number is also written to the CSV and the one page print card. That matters more than it sounds: a printed card that says speech measured at minus 17.5 dBFS, floor at minus 63.1 dBFS, ratio 45.6 dB, zero clipped samples, is a record somebody else can check, while a green tick alone is an opinion.
Frequently asked questions
Why does the meter show −∞ dBFS (Silence) instead of a number?
Because the level of a digital silence is genuinely negative infinity: twenty times log base ten of an amplitude of zero has no finite value. Rather than print a raw error token or a bare infinite sign on a page a person is reading, the formatter turns that exact state into the sentence −∞ dBFS (Silence), and the meter bar collapses to zero width. The CSV carries the same wording, so the screen, the spreadsheet and the print card never disagree.
How long should the noise-floor calibration be and when should I repeat it?
Three seconds of quiet is enough to average out a single chair creak while staying short enough that nobody gets bored. Repeat the calibration whenever you change something that affects the capture path: a different device, a different room, or a different combination of echo cancellation, noise suppression and auto gain control. Those three processors change the noise floor directly, so a calibration taken with them on does not describe a take made with them off.
What counts as a good signal-to-noise ratio for speech?
The ratio is speech dBFS minus noise-floor dBFS. Below about 20 dB the room starts to compete with the voice and noise suppression becomes audible as pumping; between 30 and 45 dB a normal call sounds clean; above 45 dB the room is effectively silent relative to the speaker. A treated room with a condenser at twenty centimetres commonly measures a floor near minus 62 dBFS and speech near minus 18 dBFS, which is a 44 dB ratio.
Does the clipping counter count samples or seconds?
It counts samples, so it is a severity measure rather than a duration. A single clipped sample at 48 kHz lasts about twenty-one microseconds and is inaudible; a run of hundreds produces the flat-topped distortion you can hear. Because the count is reported exactly, it doubles as a comparison tool: the same sentence recorded twice at different gains will show a very different count if one take is over the limit.
More microphone tests in this workbench
Every page shares the same Web Audio capture pipeline, the same honest track.getSettings() readout, the same local 16-bit PCM WAV encoder, the same zero-upload boundary, and the same CSV plus one page print output.
Specifications and engineering notes
Every level, latency figure, WAV byte and permission state on this site follows a public browser or audio-engineering specification rather than a private measurement.
- W3C Media Capture and Streams — getUserMedia audio constraints (echoCancellation, noiseSuppression, autoGainControl), MediaStreamTrack.getSettings() and the NotAllowedError / NotFoundError / NotReadableError names.
- W3C Web Audio API — AudioContext.baseLatency, AudioContext.outputLatency, AnalyserNode.getFloatTimeDomainData and getByteFrequencyData, and buffer duration as frames divided by sample rate.
- ITU-R BS.1770 and EBU R 128 loudness practice — Twenty times log base ten for dBFS conversion, 0 dBFS at full scale, and the −24 to −12 dBFS working band for spoken word.
- Microsoft RIFF / WAVE specification — The 44-byte RIFF, WAVE, fmt and data header, format tag 1 for uncompressed PCM, 16-bit little-endian samples from −32768 to 32767, and data byte length equal to frames times two.
- IEEE Harvard sentences (public domain speech material) — Phonetically balanced sentences used for the read-aloud rotation, chosen because they exercise plosives, fricatives and sentence-final tails.
- WCAG 2.1 contrast and keyboard guidance — The 4.5 to 1 text contrast ratio and a focus order that survives a re-render, both verified on the built pages and on the printed card.
Every capture, level, take and WAV file is produced locally by the Web Audio API inside this tab and sent only to your own output device. No audio upload, no account, no third-party player, and no microphone prompt until you press Start Live Mic.